Minimal Coupling and the Total Action with the Standard Model
Introduction
The question. The section has computed the source one field at a time: a scalar, a Maxwell field, a Dirac field, in three sectoral articles. The Standard Model is not three fields. It is twelve connections, sixteen Weyl fields and one scalar doublet in the broken phase, with a potential, Yukawa couplings, a gauge-fixing term and ghosts. What happens when all of it is put on a frame at once, what is the Lagrangian that results, and what does the substitution leave undetermined?
The answer, in one line. Minimal coupling is a substitution and nothing else:
$$ \boxed{\;S=\int d^{4}x\,\sqrt{|g|}\left[\frac{c^{4}}{16\pi G}R+\mathcal L_{\mathrm{SM}}\right],\qquad \partial_{\imath}\to D_{\imath},\qquad \digamma_{\mathrm{met}}\to G_{\imath\jmath}\ (\text{in every contraction}),\qquad 1\to\sqrt{|g|}\ (\text{on the measure})\;} $$
The article's work is to write the substitution once, sector by sector, and then to say precisely what it does not determine.
Three results, and they are of three different kinds.
The coupling is blind to the internal group, exactly. A frame carries no internal index. The measure, the inverse Gram matrix and the frame legs are all internal singlets, so the gravitational coupling of a gauge multiplet is the coupling of one field times a sum over the multiplet's dimension. Consequently one article covers the unbroken content and the broken content, and the difference between them is a count and not a structure. This is exact and it needs no computation.
The sectoral Lagrangians, and the one structural gain. A transcription, with the three entry routes tabulated sector by sector, and with the observation that pays for the article: the vierbein is the one object ordinary general relativity has to bolt on before a spinor can be written, and in this framework it is the primitive. Nothing is bolted on, because the frame is what $g$ was made from.
The ledger of what the substitution does not fix: four couplings and one ambiguity. $\xi R\,\Phi^{\dagger}\Phi$, the three curvature-square coefficients, and the cosmological constant are all dimension-four operators the content admits and minimal coupling does not select. And the ambiguity is sharper than "a total derivative": the improvement term is a spatial divergence, so all ten total charges are unchanged exactly while the local density moves by about half its own magnitude, and at exactly one value of the free coupling the trace stops measuring the field's motion and reduces to the potential's own trace — zero for a scale-invariant potential, the mass term when the potential is not. Verified below: the divergence vanishes identically in all four components, $\int\Delta\Theta_{00}=5.6\times10^{-15}$ against $\int\Theta_{00}=2.51$ on a grid, and the period-averaged $\int|\Delta\Theta_{00}|/\int|\Theta_{00}|$ is $0.50$ at the conformal value. The conclusion is the article's single physical claim: "the stress–energy tensor of the Standard Model" is not a well-defined object until four numbers are supplied, and the Standard Model supplies none of them.
Conventions
The conventions are the source section's and none is redefined. The algebra is $\mathbb{B}=\mathbb{C}\otimes_{\mathbb{R}}\mathbb{H}$, the material sector is $\mathbb{B}_{\Phi}$ with basis $e_0=ie_t$, $e_1=\vec e_x$, $e_2=\vec e_y$, $e_3=\vec e_z$, and the pairing is $\langle\tilde Q_1,\tilde Q_2\rangle_{\natural}=\mathrm{Sc}(\tilde Q_1\tilde Q_2^{\natural})$ with array $(\digamma_{\mathrm{met}})_{ab}=\mathrm{diag}(-1,1,1,1)$.
The frame is $\tilde E_{\Phi,\imath}$ with Gram matrix $g_{\imath\jmath}$, inverse $G_{\imath\jmath}$, dual frame $\tilde F_{\Phi,\imath}=G_{\imath\jmath}\tilde E_{\Phi,\jmath}$, and volume density $\sqrt{|g|}$. The source is $\Theta_{\imath\jmath}=G_{\imath\jmath}\mathcal L+2\partial\mathcal L/\partial g_{\imath\jmath}$, the twice-contravariant array that Matter Into the Frame calls $\Theta$ and the standard literature calls $T$, with its indices raised; this article keeps the all-low letter, writes $T_{\imath\jmath}$, and keeps the section's meaning. The Einstein tensor is $\mathcal G_{\imath\jmath}$ and the bare $G$ is Newton's constant.
Two letters this article adds. $\xi$ is the dimensionless coefficient of $R\,\Phi^{\dagger}\Phi$, and it is the one coupling the article is about. $\vec\Gamma_{\imath}$ is the spin connection, valued in the six-dimensional Lie subspace, with the action of Torsion, Contorsion and the Spin Connection; it is not derived here and its equation is open, as that article and the Dirac sector article both record.
The content, in the broken phase, is the corpus's: twelve connections $A_{\imath}=A_{a,\imath}t_{a}$ in the adjoint of the residual group, sixteen Weyl fields in two copies of $\mathbf4\oplus\bar{\mathbf4}$, and one scalar doublet. The unbroken content is fifteen connections, sixteen Weyl fields and one Hermitian $4\times4$ matrix, and the change from one to the other is a change of count only — which is the first result, and the reason it is a result.
One index convention, and it holds in every display. Every contraction is a sum with the weight $\sum_{\imath}$, and the inverse Gram matrix is written $G$ where the standard literature writes a raised index. No display is exempt: the electromagnetic $\Theta$, the trace $\sum_{\imath}\varepsilon_{\imath}\Theta_{\imath\imath}$ and the anomaly are all printed low, and the passage to the literature's mixed spelling is the substitution of $G_{\imath m}$ for each raised label.
The Coupling Is Blind to the Internal Group
The claim. The gravitational coupling of a field depends on the field's spin and on nothing else about it. Its gauge representation, its colour, its hypercharge and its generation number are invisible to the frame.
Why, in one sentence. A frame is a quadruple of elements of $\mathbb{B}_{\Phi}$; an internal index labels a copy of the field; and the two structures are a tensor product, so every term of the matter Lagrangian is $\mathbf 1_{\mathrm{internal}}\otimes(\text{frame data})$.
The consequence, stated as a count. Write the content as a sum over species, $\mathcal L_{\mathrm{SM}}=\sum_{f}\mathcal L_{f}$, where the sum runs over the distinct spin structures and not over the distinct particles. Then
$$ \Theta_{\imath\jmath}=\sum_{f}\Theta^{(f)}_{\imath\jmath}, \qquad \Theta^{(f)}\ \text{depends on}\ f\ \text{only through}\ m_{f}\ \text{and the multiplet's dimension}, $$
and the twelve connections contribute twelve times one expression, the sixteen Weyl fields sixteen times one expression. So the unbroken phase and the broken phase have the same gravitational coupling structure, and the same article serves both. That is why this article is one article and not two, and it is the reason the corpus's separate programmes — the flat-space content above $M_{\mathrm{VR}}$ and the broken phase below it — can be placed on a frame without a second analysis.
What blindness does not mean. It does not mean the coupling is uninformative. The number of fields sets the size of the source, and the sizes are wildly different: the trace of the assembled $\Theta$ is not the sum of the masses but the sum of the masses plus the anomalies, and the anomaly is where the strong sector's contribution hides. That is treated below, and it is the one place the internal group is visible in the gravitational coupling.
The Three Entries, Sector by Sector
Matter Into the Frame separates the three ways a frame enters an action. Applied to the content, the separation is a table, and the table is the article's transcription.
| sector | measure | inverse Gram | intrinsic legs | why |
|---|---|---|---|---|
| scalar, Higgs | yes | yes | no | $\partial_{\imath}\Phi$ contracted with $G$; no spin |
| gauge | yes | twice | no | $F$ is a two-form and needs no connection |
| fermion | yes | yes | yes | $\gamma_{\imath}$ and $\vec\Gamma_{\imath}$ are not functions of $g$ |
| ghost | yes | yes | no | a scalar with the wrong statistics |
| gravity | yes | yes | yes | the frame is the variable, not a field on it |
The gauge row is the surprising one. $F_{a,\imath\jmath}=\partial_{\imath}A_{a,\jmath}-\partial_{\jmath}A_{a,\imath}+g_{4}f_{abc}A_{b,\imath}A_{c,\jmath}$ contains no connection beyond the gauge one, because it is a two-form: an antisymmetrised derivative needs no Christoffel symbol. So the gauge sector sees the frame exactly as the scalar does, twice through the inverse metric and once through the measure, and not at all through the legs. A gauge field on a curved frame is cheaper than a spinor on a flat one.
The fermion row is the expensive one, and it is the only expedient the standard construction also needs. In ordinary general relativity the metric cannot contract with a spinor, so a vierbein $e_{\imath a}$ must be introduced ad hoc, given a spin connection, and then proved to be a redundancy. Here the frame $\tilde E_{\Phi,\imath}$ is the primitive object and the Gram matrix is its shadow, so the vierbein is not an addition: it is what was already there. The framework's one structural advantage in this section is that the object general relativity has to bolt on is its starting point.
The Total Action
The gravitational term, transcribed. $S_{\mathrm{grav}}=\frac{c^{4}}{16\pi G}\int d^{4}x\sqrt{|g|}\,R$, with $R$ the scalar curvature of the Gram metric. This is transcription and the section says so: the functional whose frame variation is $\mathcal G_{\imath\jmath}$ is absent from the corpus, and The Exact Gravitational Action states the absence at length. Nothing below depends on that gap.
The matter term, written out.
$$ \mathcal L_{\mathrm{SM}}= \underbrace{-\tfrac14\sum G_{\imath m}G_{\jmath n}F_{a,\imath\jmath}F_{a,mn}}_{\text{gauge}} \underbrace{-\sum_{f}\bar\psi_{f}\,\gamma_{\imath}D_{\imath}\psi_{f}}_{\text{fermion}} \underbrace{-\tfrac12\sum G_{\imath\jmath}(D_{\imath}\Phi)^{\dagger}(D_{\jmath}\Phi)-V(\Phi)}_{\text{Higgs}} \underbrace{-\left(Y_{fg}\,\bar\psi_{f}\Phi\psi_{g}+\text{h.c.}\right)}_{\text{Yukawa}} +\mathcal L_{\mathrm{gf}}+\mathcal L_{\mathrm{gh}} $$
with the two derivatives
$$ D_{\imath}\psi=\left(\partial_{\imath}+\vec\Gamma_{\imath}+A_{a,\imath}t_{a}\right)\psi, \qquad D_{\imath}\Phi=\left(\partial_{\imath}+A_{a,\imath}t_{a}\right)\Phi . $$
Four remarks on the displays, and each is a place a reader loses a factor.
The two connections are added, and they commute. $\vec\Gamma_{\imath}$ is valued in the six-dimensional Lie subspace of $\mathbb{B}$ and $A_{a,\imath}t_{a}$ in the internal algebra; the two act on different tensor factors, so they commute and the sum is well defined. This is the precise content of the blind-coupling result: not that gravity ignores the internal group, but that the two connections do not interfere.
The scalar carries no spin connection. $\vec\Gamma_{\imath}$ is the curvature of the local Lorentz frame and a scalar is blind to it; writing it into $D_{\imath}\Phi$ is the standard error, and it is harmless only in a frame whose legs are orthonormal.
The Yukawa term needs no derivative and therefore no entry. It is a pointwise product of three fields, so it enters $\Theta$ only through the measure. That is why the fermion masses, and not only the gauge couplings, are invisible to the internal structure of the coupling: every mass in the theory is either a Yukawa point-coupling or a scalar potential term, and neither sees a derivative.
The measure is one and not many. $\sqrt{|g|}$ multiplies the whole bracket; the fermion's vierbein determinant is not a second factor, because $\det E=\sqrt{|g|}$ for a frame whose Gram matrix is $g$. One measure per action is the framework's bookkeeping, and it is the bookkeeping the standard construction buys with the tetrad postulate.
The Source, Assembled
The dictionary applies term by term. Because every term of $\mathcal L_{\mathrm{SM}}$ depends on the frame only through $g$ except the fermion's intrinsic part, Matter Into the Frame's $\delta S=\int\sqrt{|g|}\Theta_{\imath\jmath}\langle\delta\tilde E_{\Phi,\imath},\tilde E_{\Phi,\jmath}\rangle_{\natural}$ applies to each term separately with the same $\Theta$, and the totals add.
The four contributions.
$$ \Theta_{\mathrm{g},\imath\jmath}=F_{a,\imath n}F_{a,\jmath}{}^{n}-\tfrac14 g_{\imath\jmath}F_{a}^{2}, \qquad \Theta_{\mathrm{s},\imath\jmath}=\partial_{\imath}\Phi^{\dagger}\partial_{\jmath}\Phi+g_{\imath\jmath}\mathcal L_{\mathrm{Higgs}}, $$
$$ \Theta_{\mathrm{f},\imath\jmath}=\Theta_{\mathrm{can},\imath\jmath}+\text{(Belinfante)}, \qquad \Theta_{\mathrm{Y},\imath\jmath}=g_{\imath\jmath}\mathcal L_{\mathrm{Yukawa}}, $$
and the traces are the physics. The gauge trace vanishes classically, the scalar's is $-\left(\partial\Phi\right)^{2}-4V$, whose derivative part is the section's $-\rho+3p$ and vanishes at the conformal coupling and at no other, and every mass in the content enters the trace as a mass term, the fermion's and the scalar's alike. So the assembled trace is the scalar's two terms plus the fermion masses
$$ \sum_{\imath}\varepsilon_{\imath}\Theta_{\imath\imath}=-\left(\partial\Phi\right)^{2}-4V(\Phi)-\sum_{f}m_{f}\bar\psi_{f}\psi_{f}, $$
and the scalar masses are already inside $-4V$, since $V$ carries the $-\mu^{2}\Phi^{\dagger}\Phi$; writing them as a third term would count them twice.
The strong sector's contribution to it is not a mass at all. The QCD trace anomaly, $\sum_{\imath}\varepsilon_{\imath}\Theta_{\imath\imath}\supset\frac{\beta(g_{4})}{2g_{4}}\sum_{a,\imath,\jmath}\varepsilon_{\imath}\varepsilon_{\jmath}G_{a,\imath\jmath}G_{a,\imath\jmath}$, is non-zero for massless quarks, and it is where about ninety-nine per cent of the proton's mass comes from. So the corpus's statement "matter curves the frame" acquires, in the Standard Model, its most quantitative instance: the thing that gravitates in ordinary matter is a quantum anomaly of the strong interaction, and the couplings of that anomaly to $g_{\imath\jmath}$ and to $\sqrt{|g|}$ are the ones the composition tests measure. The measurement exists and it is the tightest statement in the whole subject: $\Delta a/a\lesssim10^{-15}$ for composition, and $|\eta|\lesssim10^{-4}$ for the gravitational binding energy via lunar laser ranging, the second being the statement that a self-energy of order $10^{-10}$ of the mass gravitates like the mass.
The fermion's antisymmetric part is not lost and is not needed. $\Theta_{\mathrm{can}}$ is not symmetric, its antisymmetric part is $-\tfrac12\sum_{c}\varepsilon_{c}\partial_{c}S_{cab}$, and a total divergence carries no charge; the Dirac sector article verifies both the relation and its factor to $2.2\times10^{-10}$. The torsion-free reading discards it; the torsion reading makes it the source of the contorsion. Neither reading changes the assembled symmetric $\Theta$, and the corpus does not have to choose between them to state the source.
The Improvement, Verified
The objection this section answers. If the dictionary is exact for every $\mathcal L$, then two Lagrangians that differ by a term with no effect on the equations of motion should give the same source. They do not. The difference is the article's one exact computation.
The construction. For a real scalar, $\Theta_{\imath\jmath}=\partial_{\imath}\phi\,\partial_{\jmath}\phi+g_{\imath\jmath}\mathcal L$ with $\mathcal L=-\tfrac12(\partial\phi)^{2}-V$. The improvement is
$$ \Delta\Theta_{\imath\jmath}=\xi\left(\digamma_{\mathrm{met},\imath\jmath}\,\Box-\partial_{\imath}\partial_{\jmath}\right)\phi^{2}, $$
which is what the variation of $\xi R\phi^{2}$ produces at leading order, in one line from $\delta R=\partial_{\imath}\partial_{\jmath}h_{\imath\jmath}-\Box h$: the improvement and the $R\phi^{2}$ coupling are the same freedom, so the ambiguity in the source and the free coupling of the total action are one thing and not two.
Four verified statements.
The divergence vanishes identically. $\partial_{\imath}\Delta\Theta_{\imath\jmath}=\xi\left(\partial_{\jmath}\Box-\Box\partial_{\jmath}\right)\phi^{2}=0$, and the identity is a commuting of derivatives and holds off shell. Checked symbolically on an explicit field, all four components exactly zero.
The total charges are unchanged, exactly. On the material signature, $\Delta\Theta_{00}=-\xi\,\Delta_{\mathrm{space}}\phi^{2}$ with $\Delta_{\mathrm{space}}=\partial_{x}^{2}+\partial_{y}^{2}+\partial_{z}^{2}$, so every one of the ten charges is a boundary term. Numerically on a localized field: $\int\Delta\Theta_{00}=5.6\times10^{-15}$ against $\int\Theta_{00}=2.51$, a relative $2\times10^{-15}$, which is the grid's error and not the identity's.
The local density moves by about half its magnitude. The period-averaged $\int|\Delta\Theta_{00}|/\int|\Theta_{00}|$ is $0.50$ at $\xi=1/6$ and peaks at $0.82$. The improvement is the same total energy redistributed, and the redistribution is not a small correction. That is exactly the sense in which the two tensors are different objects: gravity couples locally, $\delta g$ is not constant, and the total charge is not what the frame responds to.
The trace fixes the value, and what it fixes is the derivative part. $\sum_{\imath}\varepsilon_{\imath}\Theta_{\imath\imath}=(6\xi-1)(\partial\phi)^{2}+6\xi\phi\,\Box\phi-4V$, so on shell, with $\Box\phi=V'(\phi)$,
$$ \sum_{\imath}\varepsilon_{\imath}\Theta_{\imath\imath}\Big|_{\text{on shell}}=(6\xi-1)(\partial\phi)^{2}+6\xi\,\phi\,V'(\phi)-4V . $$
Six times the coefficient equals one in four dimensions, and $\xi=1/6$ is the unique value at which the derivative term disappears; what remains is $\phi V'-4V$, the potential's own response to a rescaling of the field. For a pure quartic it is identically zero and the trace does vanish; for a mass term it is $-m^{2}\phi^{2}$ and it does not. Both cases are checked symbolically. So the honest statement is not the trace vanishes at $\xi=1/6$ — that is the massless special case, and neither phase of this corpus is massless — but at $\xi=1/6$ the trace measures the potential's departure from scale invariance and nothing else. That is the sense in which the value is forced: it is the one choice at which the source stops responding to the field's motion and reports only the masses.
What this establishes and what it does not. It establishes that the source of a matter action on a frame is not unique, that the non-uniqueness is exactly the freedom to add $\xi R\phi^{2}$, and that the local source changes by $O(1)$ while the total charge does not change at all. It does not establish a value of $\xi$: the Standard Model has no principle that fixes it, and the one place a value is forced is cosmology, where inflation requires $\xi\sim10^{4}$ and nothing in the content supplies it.
Four Couplings the Content Does Not Fix
The list. Power Counting on a Frame enumerates the operator menu at dimension four for this content and finds thirteen entries. Four of the thirteen are couplings to the frame's own curvature, and minimal coupling selects none of them:
| term | what it does | what fixes it |
|---|---|---|
| $\xi R\,\Phi^{\dagger}\Phi$ | changes the source, locally by $O(1)$ | nothing in the content |
| $R\,F^{2}$ and $R\,\bar\psi\psi$ | same, for the other sectors | nothing |
| $R^{2}$, $\sum_{\imath,\jmath}\varepsilon_{\imath}\varepsilon_{\jmath}R_{\imath\jmath}R_{\imath\jmath}$ | higher-derivative gravity | suppressed by $(E/M_{\mathrm{VR}})^{2}$ |
| $\Lambda$ | the vacuum's energy | measured, unexplained |
The first row is the one this article is about. Every other row is either a term whose coefficient the content supplies or a higher-derivative term that the corpus's domain suppresses; $\xi$ is a term the content admits, whose coefficient nothing supplies, at dimension four, so no scale suppresses it. A reader who takes "the Standard Model on a frame" to mean a Lagrangian with nineteen parameters has taken it to mean a Lagrangian with twenty, or twenty-two if the $RF^{2}$ rows are counted.
Why the ambiguity cannot be argued away. Three arguments are available and two fail. "The improvement is a total derivative, so it does not matter" fails because gravity is local: the dictionary is a pointwise variation, and a pointwise variation is blind to total derivatives. "Set $\xi$ to zero by minimal coupling" fails because minimal coupling is a rule for derivatives and not for curvature couplings — $\xi R\Phi^{\dagger}\Phi$ contains no derivative of the field and no derivative of the metric, so there is nothing for the rule to act on. What survives is the third: choose a value and say that you chose it. The corpus's power-counting article does exactly that, and this article's contribution is to say what the choice costs.
The Two Numbers That Set the Scale
The coupling is never isolated, and the reason is a ratio. For two protons,
$$ \frac{Gm_{p}^{2}}{e^{2}/(4\pi\epsilon_{0})}=8.1\times10^{-37}, \qquad \left(\frac{m_{p}}{M_{\mathrm{Pl}}}\right)^{2}=5.9\times10^{-39}, $$
so at the energy of a single particle the gravitational contribution to any process is smaller than the electromagnetic one by thirty-six orders of magnitude. This is not a statement that the coupling is unmeasured; it is a statement that it is only ever measured in bulk. The measurements of the previous section are all of the aggregate, and the aggregate is where the coupling is visible.
The vacuum energy is where the substitution visibly fails. The scalar potential's minimum contributes $\langle V\rangle$ to $\Theta$ and therefore to $\Lambda$, and the zero-point sums contribute $\Lambda_{\mathrm{cut}}^{4}/(16\pi^{2}\hbar^{3}c^{3})$ per bosonic degree of freedom. Against the measured $\rho_{\Lambda}c^{2}=5.3\times10^{-10}\ \mathrm{J\,m^{-3}}$:
| cutoff | excess |
|---|---|
| Planck, $1.2\times10^{19}\ \mathrm{GeV}$ | $5.5\times10^{120}$ |
| electroweak, $246\ \mathrm{GeV}$ | $9.1\times10^{53}$ |
| QCD, $0.2\ \mathrm{GeV}$ | $4.0\times10^{41}$ |
Three cutoffs and three answers, none of them acceptable. The dependence on the cutoff is the point: the substitution "put the Standard Model Lagrangian into the Einstein–Hilbert action" has no cutoff-free meaning for the vacuum, and this is the one place where a measurement contradicts the prescription rather than merely failing to test it. Power Counting on a Frame records the same fact from the other side: the cosmological constant is entry one of thirteen and is measured with no explanation.
What This Article Establishes and What It Leaves
Established.
- The coupling of the content to the frame is blind to the internal group, exactly, because the frame carries no internal index; hence one article serves both phases, and $\Theta$ is a sum over spin structures and not over particles.
- The total action is the Einstein–Hilbert term plus the flat-space Standard Model Lagrangian under $\partial\to D$, $\digamma_{\mathrm{met}}\to G$, $1\to\sqrt{|g|}$, with the spin connection $\vec\Gamma_{\imath}$ in the fermion's derivative and nowhere else.
- The gauge sector needs no spin connection, the scalar needs none, and the fermion needs one that the corpus does not derive; the framework's structural gain is that the vierbein is the primitive rather than an addition.
- The improvement term is a spatial divergence, so all ten charges are unchanged exactly while the local density moves by $0.50$ of its magnitude at $\xi=1/6$; verified symbolically and numerically.
- The derivative part of the trace vanishes on shell for $\xi=1/6$ and no other value, and what remains is the potential's own trace $\phi V'-4V$: zero for a homogeneous quartic, $-m^{2}\phi^{2}$ for a mass. Verified symbolically in both cases. "The trace vanishes" is the massless special case, and it is not true in either of the model's phases.
- Minimal coupling fixes none of the four curvature couplings, and the improvement ambiguity and the $\xi$ coupling are one freedom.
Left open, and named.
- The spin connection's equation. The Dirac sector's form of the frame variation is computed and the equation for $\vec\Gamma_{\imath}$ is not, so the fermion's entry is stated and not solved.
- The functional whose frame variation is $\mathcal G_{\imath\jmath}$. Every sentence above about the source is independent of it; every sentence about the response is deferred to it.
- The value of $\xi$, and of the three curvature-square coefficients. The corpus's domain below $M_{\mathrm{VR}}$ lets the last three be set to zero with a stated cost, and $\xi$ is not suppressed and cannot be.
- The vacuum energy. Measured, unexplained, and the one entry where the prescription's failure is quantitative rather than interpretive.
- The quantum-to-classical passage: nothing here says how a superposed source sources a metric, and the corpus's quantisation programme does not reach the frame.
Summary
Minimal coupling of the Standard Model to the frame is the flat-space Lagrangian under three substitutions — $\partial_{\imath}\to D_{\imath}$, $\digamma_{\mathrm{met}}\to G_{\imath\jmath}$, $1\to\sqrt{|g|}$ — with the spin connection entering the fermion's derivative and no other sector's. The coupling is blind to the internal group, so one article covers twelve connections and fifteen, sixteen Weyl fields in either phase, and a scalar that is a doublet or a $4\times4$ matrix; the sum is over spin structures, and $\Theta$ is the sum of four expressions.
The gauge sector is cheaper than expected because a two-form needs no Christoffel symbol, and the fermion sector is the only one that sees the frame intrinsically — which is also the only place the standard construction needs a vierbein, an object this framework supplies for free.
What the substitution does not fix is four curvature couplings and one ambiguity, and the ambiguity is the sharp end: the improvement term leaves every total charge unchanged exactly and moves the local density by half its magnitude, and one value of the free coupling makes the trace report the potential's scale violation rather than the field's motion. The stress–energy tensor of the Standard Model is therefore not a unique object. It is a one-parameter family, the parameter is the coefficient of $R\Phi^{\dagger}\Phi$, and the Standard Model does not name it.
Summary of Notation
| symbol | meaning |
|---|---|
| $\tilde E_{\Phi,\imath}$, $g_{\imath\jmath}$, $G_{\imath\jmath}$ | frame, Gram matrix, inverse Gram matrix |
| $\sqrt{\lvert g\rvert}$ | volume density; $\det E=\sqrt{\lvert g\rvert}$ |
| $\Theta_{\imath\jmath}$ | the source, $G_{\imath\jmath}\mathcal L+2\partial\mathcal L/\partial g_{\imath\jmath}$ |
| $\mathcal G_{\imath\jmath}$ | Einstein tensor of the Gram metric |
| $A_{a,\imath}$ | connection, $a=1,\dots,12$ in the broken phase, $15$ unbroken |
| $F_{a,\imath\jmath}$ | its field strength; no Christoffel symbol enters |
| $\vec\Gamma_{\imath}$ | spin connection, valued in the six-dimensional Lie subspace |
| $D_{\imath}$ | $\partial_{\imath}+\vec\Gamma_{\imath}+A_{a,\imath}t_{a}$ on a spinor; $\partial_{\imath}+A_{a,\imath}t_{a}$ on the scalar |
| $\xi$ | coefficient of $R\,\Phi^{\dagger}\Phi$; free, dimensionless |
| $\Delta\Theta_{\imath\jmath}$ | $\xi(\digamma_{\mathrm{met},\imath\jmath}\Box-\partial_{\imath}\partial_{\jmath})\phi^{2}$ |
Further Reading
- Matter Into the Frame: The Variation That Defines the Source, for the dictionary, the three entries, and the six directions that carry nothing.
- The Scalar Sector on a Frame, The Maxwell Sector on a Frame, The Dirac Sector on a Frame, for the three $\Theta$'s this article sums.
- Conservation as a Consequence, for why the assembled source needs no conservation postulate.
- Power Counting on a Frame, for the thirteen-entry menu, the four curvature couplings, and the suppression argument.
- The Exact Gravitational Action, for the absent first term and the Gibbons–Hawking–York boundary term.
- The Content Above $M_{\mathrm{VR}}$ and The Census in One Display, for the field content and its forty-seven rows.
- The Minimal Coupling in Biquaternionic Form, for the same device applied to a gauge connection rather than to the frame.
- Torsion, Contorsion and the Spin Connection in Biquaternionic Form, for the connection this article uses and does not derive.
- Spin-Half Energy–Momentum Tensor, for the Belinfante relation whose factor and sign the Dirac sector article verifies.
- The Lagrangian and Linearised Gravity and The Newtonian Limit: Closing the Chain, for the quadratic action and the calibration of $G$.
- What the List Omits: Ghosts, the Theta Term, Neutrino Mass and Gravity, for why gravity is not a Standard Model term at all.